The trach tube bypasses these mechanisms, so that the air moving through the tube is cooler, dryer and not as clean. In response to these changes, the body produces more mucus. Suctioning clears mucus from the tracheostomy tube and is essential for proper breathing. Also, secretions left in the tube could become contaminated and a chest infection could develop. Avoid suctioning too frequently as this could lead to more secretion buildup.
Removing mucus from trach tube without suctioning
- Bend forward and cough. Catch the mucus from the tube, not from the nose and mouth.
- Squirt sterile normal saline solutions (approximately 5cc) into the trach tube to help clear the mucus and cough again.
- Remove the inner tube (cannula).
- Suction.
- Call 911 if breathing is still not normal after doing all of the above steps.
- Remove the entire trach tube and try to place the spare tube.
- Continue trying to cough, instill saline, and suction until breathing is normal or help arrives.
When to suction
Suctioning is important to prevent a mucus plug from blocking the tube and stopping the patient's breathing. Suctioning should be considered- Any time the patient feels or hears mucus rattling in the tube or airway
- In the morning when the patient first wakes up
- When there is an increased respiratory rate (working hard to breathe)
- Before meals
- Before going outdoors
- Before going to sleep
How to suction
EquipmentClean suction catheter (Make sure you have the correct size)
Distilled or sterile water
Normal saline
Suction machine in working order
Suction connection tubing
Jar to soak inner cannula (if applicable)
Tracheostomy brushes (to clean tracheostomy tube)
Extra tracheostomy tube
- Wash your hands.
- Turn on the suction machine and connect the suction connection tubing to the machine.
- Use a clean suction catheter when suctioning the patient. Whenever the suction catheter is to be reused, place the catheter in a container of distilled/sterile water and apply suction for approximately 30 seconds to clear secretions from the inside. Next, rinse the catheter with running water for a few minutes then soak in a solution of one part vinegar and one part distilled/sterile water for 15 minutes. Stir the solution frequently. Rinse the catheters in cool water and air-dry. Allow the catheters to dry in a clear container. Do not reuse catheters if they become stiff or cracked.
- Connect the catheter to the suction connection tubing.
- Lay the patient flat on his/her back with a small towel/blanket rolled under the shoulders. Some patients may prefer a sitting position which can also be tried.
- Wet the catheter with sterile/distilled water for lubrication and to test the suction machine and circuit.
- Remove the inner cannula from the tracheostomy tube (if applicable). The patient may not have an inner cannula. If that is the case, skip this step and go to number 8.
a. There are different types of inner cannulas, so caregivers will need to learn the specific manner to remove their patient's. Usually rotating the inner cannula in a specific direction will remove it.
b. Be careful not to accidentally remove the entire tracheostomy tube while removing the inner cannula. Often by securing one hand on the tracheostomy tube?s flange (neck plate) one can/ will prevent?accidental removal.
c. Place the inner cannula in a jar for soaking (if it is disposable, then throw it out). - Carefully insert the catheter into the tracheostomy tube. Allow the catheter to follow the natural curvature of the tracheostomy tube. The distance to the location of catheter becomes easier to determine with experience. The least traumatic technique is to pre-measure the length of the tracheostomy tube then introduce the catheter only to that length. For example if the patient?s tracheostomy tube is 4 cm long, place the catheter 4 cm into the tracheostomy tube. Often, there will be instances when this technique of suctioning (called tip suctioning) will not clear the patient?s secretions. For those situations, the catheter may need to be inserted several mm beyond the end of the tracheostomy tube (called deep suctioning). With experience, caregivers will be able to judge the distance to insert the tracheostomy tube without measuring.
- Place your thumb over the suction vent (side of the catheter) intermittently while you remove the catheter. Do not leave the catheter in the tracheostomy tube for more than 5-10 seconds since the patient will not be able to breathe well with the catheter in place.
- Allow the patient to recover from the suctioning and to catch his/her breath. Wait for at least 10 seconds.
- Suction a small amount of distilled/sterile water with the suction catheter to clear any residual debris/secretions.
- Insert the inner cannula from extra tracheostomy tube (if applicable).
- Turn off suction machine and discard catheter (clean according to step 3 if to be reused).
- Clean inner cannula (if applicable).
No comments: